Steel Fire Doors
Steel fire doors are the workhorse of a building's passive fire protection. They close a compartment opening, hold back fire and smoke for the rating period the project specifies, and are built to survive daily traffic in stairwells, corridors, service shafts and plant rooms. Our steel range covers single leaf, double leaf, glazed and unglazed configurations, painted or with a wood-grain finish, and is supplied as a complete door set: leaf, frame, closer, hinges, lock and intumescent seals. Every set is made to the opening size on the project schedule, so frames fit the structural opening rather than being adjusted on site. Ratings, hardware brands and finish options are confirmed against the certificate the factory holds for the destination market.
En esta categoría
- Single Leaf Steel Fire DoorA single leaf steel fire door for stairwell, corridor and plant room openings, supplied as a complete set.
- Double Leaf Steel Fire Door with Vision PanelsA double leaf steel fire door with factory-fitted vision panels, for corridors that need sight lines through the opening.
Criterios de selección
- Match the rating class to the compartment, not to the product catalogue: stairwell enclosures usually carry a higher requirement than corridor partitions.
- Order as a complete set (leaf + frame + hardware + seals). A certified leaf fitted with uncertified hardware does not deliver the rated assembly.
- For high-traffic corridors, specify a door closer with a back-check function and a hold-open device tied to the fire alarm.
- Confirm the wall type before releasing the frame: masonry, drywall and steel stud openings need different frame profiles and fixing details.
Preguntas frecuentes
- Do you supply the door and the frame together?
- Yes. Sets are quoted as leaf, frame, hardware and seals, made to the opening size on your schedule. Supplying the two separately is the most common cause of site delays.
- Can the leaf carry a vision panel?
- Yes, glazed apertures can be factory-fitted. The glass type must match the rating class of the assembly, so it is specified together with the door rather than added later.
- Which documents come with an order?
- Test reports and certificates the factory holds for the ordered configuration, plus packing lists and drawings for approval. Certificates are only stated for configurations actually covered.
- Can we order one set as a sample?
- Sample quantities are handled case by case. Send the opening size and rating so the factory can confirm what is feasible before an order is placed.
Categorías relacionadas
- Steel Fire DoorsSteel fire doors are the workhorse of a building's passive fire protection
- Steel & Wood Fire DoorsA steel and wood fire door keeps the structural discipline of a steel door and gives it the face a guest will actually see
- Wooden Fire DoorsTimber fire doors are specified where the interior has to look like an interior
- Stainless Steel Fire DoorsStainless steel fire doors are chosen where cleaning agents, humidity and hygiene rules would destroy a painted finish within a couple of years
- Glass Fire DoorsA glass fire door keeps the compartment line intact without turning a lobby or atrium into a corridor of blank panels
- Fire ShuttersA fire shutter closes an opening that is too wide, too tall or too busy for a swing door: shopping centre malls, car park ramps, warehouse transfer bays and plant room fronts
- Fire Rated WindowsFire rated windows close the parts of a compartment line that have to stay transparent: external walls facing a boundary, stairwell enclosures, corridor screens and plant room observation openings
- Refuge Room Fire DoorsA refuge room door is the last line between a place people are told to wait and the fire they are waiting out
- Shaft Fire DoorsShaft fire doors are the small, heavily used access panels of a building's service core
- Oversized & Industrial Fire DoorsOversized fire doors solve the openings that standard door schedules cannot: factory bays, warehouse transfer points, plant room fronts and industrial buildings where equipment has to pass through the compartment line